-4-
T50 TOOL SPECIFICATIONS
All screws and nuts are metric.
FASTENER SPECIFICATIONS:
T
OOL AIR FITTING:
This tool uses a free-flow connector plug, 1/4” N.P.T. The minimum inside diameter should
be .200” (5mm). The fitting must be capable of discharging tool air pressure when
disconnected from the air supply.
OPERATING PRESSURE:
The operating pressure of the T50 tool is 70 to 100 p.s.i. (4.9 to 7.1 kg/cm
2
).
Select the operating pressure within this range for best fastener performance.
DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE.
AIR CONSUMPTION:
Model T50 requires 3.0 cubic feet per minute (.08 cubic meters) of free air to operate at
the rate of 100 fasteners per minute, at 80 p.s.i. (5.6kg/cm2). Take the actual rate at
which the tool will be run to determine the amount of air required. For instance, if your
fastener usage averages 50 fasteners per minute, you need 50% of the tool's c.f.m. of
free air which is required for running at 100 fasteners per minute.
OPERATION
MODEL LENGTH HEIGHT WIDTH WEIGHT
T50S2 14.25” (362mm) 10.75” (273mm) 3.00” (76mm) 5.5lb.(2.5kg.)
T50S4 14.25” (362mm) 10.75” (273mm) 3.00” (76mm) 5.2lb.(2.35kg.)
T50S5 14.25” (362mm) 10.75” (273mm) 3.00” (76mm) 5.1lb.(2.3kg.)
MODEL STAPLE SERIES CROWN WIDTH WIRE SIZE MAXIMUM LEG LENGTH
T50S2 S2-16 Ga. 1” (25mm) .062” (1.58mm) 2-1/8” (55mm)
T50S4 S4-16 Ga. 1/2” (25mm) .062” (1.58mm) 2-1/8” (55mm)
T50S5 S5-17 Ga. 7/16” (25mm) .054” (1.37mm) 2-1/8” (55mm)
STANLEY-BOSTITCH OFFERS THREE TYPES OF OPERATION FOR THIS SERIES TOOL.
CONTACT TRIP
The common operating procedure on “Contact Trip” tools is for the operator to contact the work
to actuate the trip mechanism while keeping the trigger pulled, thus driving a fastener each time
the work is contacted. This will allow rapid fastener placement on many jobs, such as
sheathing, decking and pallet assembly.
All pneumatic tools are subject to recoil when driving fasteners. The tool may bounce, releasing
the trip, and if unintentionally allowed to recontact the work surface with the trigger still actuated
(finger still holding trigger pulled) an unwanted second fastener will be driven.
SEQUENTIAL TRIP
The Sequential Trip requires the operator to hold the tool against the work before pulling the
trigger. This makes accurate fastener placement easier, for instance on framing, toe nailing and
crating applications.
The Sequential Trip allows exact fastener location without the possibility of driving a second
fastener on recoil, as described under “Contact Trip”.
The Sequential Trip Tool has a positive safety advantage because it will not accidentally drive a
fastener if the tool is contacted against the work – or anything else – while the operator is
holding the trigger pulled.
TRIGGER OPERATED
The Trigger Operated model is cycled by actuation of the trigger only. This model does not
have a Contact Arm and is intended for use only where a Contact Arm CANNOT be used to
satisfy the requirements of the application. The Trigger Operated tool will cycle each time the
trigger is actuated.
MODEL IDENTIFICATION:
Refer to Operation Instructions on page 7 before proceeding to use this tool.
CONTACT TRIP SEQUENTIAL TRIP TRIGGER OPERATED
Identified by: Identified by: Identified by:
BLACK TRIGGER GRAY TRIGGER BLACK TRIGGER